Skip to main content

EcoSystem 50

Technical information

Performance

Energy

Thermal insulation - Uw
2.6 W/m²K
Uw Dependencies
Frame-vent: Ug 1.0W/m²K, warm edge spacer, @1.23x1.48m (92mm sight line), 24mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class 9A (600Pa)
Wind load resistance
Class C4 (1600Pa)
Acoustics - Rw(C;Ctr)
38(-1;-2) dB
Opening & closing resistance
Class 2

Safety

Burglar resistance
RC6
Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Sightlines

Min. frame width (inward opening)
48 mm
Min. vent width (inward opening)
30 mm
Min. frame-vent width (inward opening)
86 mm
Min. frame width (outward opening)
21 mm
Min. vent width (outward opening)
73 mm
Min. frame-vent width (outward opening)
99.5 mm
Depth frame
50 mm
Depth Vent
59 mm
Depth frame-vent
50 mm

Glazing

Rebate height
22 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead
Min. glass thickness - vent
4 mm
Max. glass thickness - vent
32 mm