Skip to main content

ConceptWall 60 High Insulation

Technical information

Performance

Energy

Thermal insulation - Uf
0.8 W/m²K

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E1200 (1200Pa)
Wind load resistance
E2400 (2400Pa)

Safety

Impact resistance
I5/E5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Max. height of vent
2000 mm
Min. width of vent
450 mm
Max. width of vent
2500 mm
Max. weight of vent
180 kg
Min. intertia mullion - Ix
44.6 mm
Max. intertia transom - Ix
632 mm
Min. intertia transom - Iy (glass load)
32.8 mm
Max. intertia transom - Iy (glass load)
89 mm

Sightlines

Min. width T-profile
60 mm
Min. visible width (interior view)
60 mm
Min. visible width (exterior view)
60 mm
Min. depth mullion
62.5 mm
Max. depth mullion
251.5 mm
Min. depth transom
67.2 mm

Glazing

Rebate height
25 mm
Glazing method
Dry glazing External glazing Pressure plate glazing Structural Glued Glazing Structural clamped glazing
Min. glass thickness - frame/element
22 mm
Max. glass thickness - frame/element
62 mm