Performance

Comfort

Air tightness
AE1200 (1200Pa)
Water tightness
RE1200 (1200Pa)
Wind load resistance
2000 Pa
Acoustics - Rw(C;Ctr)
43(-1;-4) dB
Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. intertia mullion - Ix
14 cm4
Max. intertia transom - Ix
534.7 cm4
Min. intertia transom - Iy (glass load)
7.9 cm4
Max. intertia transom - Iy (glass load)
59 cm4

Sightlines

Min. width T-profile
50 mm
Min. visible width (interior view)
50 mm
Min. visible width (exterior view)
50 mm
Min. depth mullion
41.5 mm
Max. depth mullion
300 mm
Min. depth transom
5 mm

Glazing

Glazing method
Dry glazing - External glazing - Pressure plate glazing - Structural clamped glazing