Skip to main content

ConceptWall 50 Transom Transom

Technical information

Performance

Comfort

Air tightness
AE1200 (1200Pa)
Water tightness
RE1200 (1200Pa)
Wind load resistance
2000 Pa
Acoustics - Rw(C;Ctr)
47(-2;-5) dB

Safety

Burglar resistance
RC2 - RC3
Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. intertia mullion - Ix
74 cm4
Max. intertia transom - Ix
937 cm4
Min. intertia transom - Iy (glass load)
23 cm4
Max. intertia transom - Iy (glass load)
68 cm4

Sightlines

Min. width T-profile
50 mm
Min. visible width (interior view)
50 mm
Min. visible width (exterior view)
50 mm
Min. depth mullion
83.5 mm
Max. depth mullion
230.5 mm
Min. depth transom
83.5 mm

Glazing

Glazing method
Dry glazing - Siliconized glazing - Pressure plate glazing